Parameter |
Default |
Description/Values |
|---|---|---|
|
Name |
n/a |
A unique descriptive name of up to 63 characters. 'none' can be used to revert to the default name. |
|
Pre-Event Reminders |
3 |
Number of event reminders to send to downstream equipment. Range from 1 to 5. |
|
Message Delta |
2000 (without parameters) |
Interval (in milliseconds) between event reminders. Range from 100 to 10,000ms (with parameters). |
|
Synchronization |
Auto |
Options are:
Note These modes only apply when time deferred SCTE-104 requests are requested from upstream SCTE-104 sources. |
|
Leap Seconds |
37 |
Leap seconds added since Jan 1, 1958 to convert UTC to TAI. |
|
Time Descriptor Period |
0 (disabled) |