Operating Environment

  • Ensure that the environment corresponds to the conditions mentioned below:

    • altitude.png Only use at altitude not exceeding 2000 meters.

    • nontropical.png Only use in not-tropical climate regions.

      • Ambient operating temperature : -5°C to 40°C.

      • Ambient operating temperature: 0°C to 40°C (for the DC adapter).

      • Ambient operating humidity: 10% to 85% (no condensation).

Important

Operating the unit out of these ranges may cause damage and void the warranty.

  • Protect the unit against rain, dust, and shocks.

  • Avoid long exposure to direct sunlight.

  • Do not obstruct the air inlets and outlets.

  • The unit relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 250V, 20A.

  • Connection to ground is made through the DC adapter to which the unit is connected. Furthermore, the unit has a protective ground terminal on the rear side.

warning.png Caution - Safety Precautions

  • Only use the DC adapter and the power cord provided by Haivision. Using another DC adapter and power cord can damage the device and void the warranty.