Skip to main content

adinsertion

The adinsertion command is used to manage the ad insertion sources.   

Note

Ad insertion is a licensed feature. For more information on licensing, see Managing Licenses

Synopsis

adinsertion ID start    
adinsertion ID stop
adinsertion ID set parameter=value [parameter=value...]
adinsertion ID get [config, stats, all]
adinsertion ID clear

Actions

Action

Description

startStarts the adinsertion source.
stopStops the adinsertion source.
setConfigures adinsertion source settings. A series of one or more parameter=value pairs can be provided at once. See Parameters below.

get

Display information on the adinsertion sources. You can select to display the configuration (config), stats, or all.

clear

Clears the adinsertion source's statistics.

help

Displays usage information for the adinsertion command.

Parameters

Parameter

Default

Description/Values

name
n/a

A unique descriptive name of up to 63 characters. 'none' can be used to revert to the default name.

synchronization
auto

Options are:

Auto - Auto-select the sync mode based on what SCTE-104 messages are being received. The priority of selected sync methods is as follows (in decreasing order): Alive, Time, System.

Alive - Force the use of the received SCTE-104 alive_request_data() messages as the means to synchronize the time between the upstream SCTE-104 source and the Makito.

Time Descriptor - Force the use of the received SCTE-104 insert_time_descriptor() messages as the means to synchronize the time between the upstream SCTE-104 source and the Makito.

System - Use the local system time as the means to synchronize the time between the upstream SCTE-104 source and the Makito. NTP should be configured as the local time source.

Note

These modes only apply when time deferred SCTE-104 requests are requested from upstream SCTE-104 sources.

leapseconds
37

Leap seconds added since Jan 1, 1958 to convert UTC to TAI.

timedescperiod
0 (disabled)

Period in seconds to force the insertion of time_descriptor. Range from 0 (disabled) to 60.

eventreminders
3

Number of event reminders to send to downstream equipment. Range from 1 to 5.

messagedelta
2000 (without parameters)

Interval in ms between event reminders. Range from 100 to 10,000ms (with parameters).

Examples

# adinsertion get all

Returns configuration information for all adinsertion sources: 

AdInsertion ID             : 1
Name                    : "HD-SDI-BNC-1"
Configuration:
Type                  : HD-SDI
Input                 : BNC-1
Synchronization Type  : AUTO
Leap Seconds          : 37 seconds
Time Descriptor Period   : Disabled
Event reminders          : 3
SCTE35 Message Delta     : 2000 ms

AdInsertion ID             : 2
Name                    : "HD-SDI-BNC-2"
Configuration:
Type                   : HD-SDI
Input                 : BNC-2
Synchronization Type  : AUTO
Leap Seconds           : 37 seconds
Time Descriptor Period   : Disabled
Event reminders          : 3
SCTE35 Message Delta     : 2000 ms

AdInsertion ID             : 3
Name                    : "HD-SDI-BNC-3"
Configuration:
Type                   : HD-SDI
Input                 : BNC-3
Synchronization Type  : AUTO
Leap Seconds           : 37 seconds
Time Descriptor Period   : Disabled
Event reminders          : 3
SCTE35 Message Delta     : 2000 ms

AdInsertion ID             : 4
Name                    : "HD-SDI"
Configuration:
Type                  : HD-SDI
Input                 : BNC-4
Synchronization Type   : AUTO
Leap Seconds           : 37 seconds
Time Descriptor Period   : Disabled
Event reminders          : 3
SCTE35 Message Delta     : 2000 ms

4 AdInsertion sources displayed.
# adinsertion 1 set synchronization=alive  

Sets the adinsertion source's synchronization mode to alive:

AdInsertion source configured successfully. 
# adinsertion 1 clear  

Clears the adinsertion statistics for source 1:

AdInsertion source stats cleared successfully. 